Apac S030ILR / S030OVR 31.02 kW Split Ducted Unit (Low Profile)

SKU: S030ILR / S030OVR

31.02 kW Cooling | 30.20 kW Heating
Apac S030ILR / S030OVR 31.02 kW Split Ducted Unit (Low Profile)

  • High static capability up to 500pa
  • Quieter operation with 12db(A) sound reduction
  • Condenser coil anti-corrosion protection | MEPS Compliant

5 Years Manufacturer’s Warranty





Model Number (Reverse Cycle)
Indoor Unit S030ILR
Outdoor Unit S030OVR
Rated Cooling
Total Capacity (kW)3 31.02
Sensible3 25.97
EER (kW/ikW)3 3.6
Rated Heating1
Total Capacity (kW) 30.2
COP 3.6
MEPS Certified Yes
Operating Range
Maximum °C 50
Minimum °C -10
Capacity Steps % 0/50/100
Compressor
Type Scroll
Starter D.O.L (Optional Soft Starter)
Qty 2
Outdoor Fan
Type Hybrid Axial
Speed Control Pressure Transducer
Qty 2
Refrigerant System
Type R410A
Charge Per Circuit kg 5.3
No of Circuits 2
Indoor Fan
Type EC Plug
Speed Control Potentiometer
Qty 2
Airflow Indoor (L/s)
Nominal 1670
Maximum 2088
Minimum 1253
Available External
Static Pressure
Pa High Static Capability (See Fan Performance Curves)
IP Rating IP44
Power Supply (Volt/Phase/Hz) 400-415V / 3Ph + N / 50Hz
Rated Load Amps4 Outdoor/Indoor/
Total
14.7/ 1.1/ 15.8
Full Load Amps5 Outdoor/Indoor/
Total
24.2/5.2/29.4
Outdoor Dimensions (mm)
Height 1190
Width 1850
Length 1425
Indoor Dimensions (mm)
Height 690
Width 1700
Length 820
Indoor and Outdoor Pipe Connection Diameter
Liquid mm (inch) 9.5 (3/8″) x 2
Gas mm (inch) 19.1 (3/4″) x 2
Nominal Weight 2. Outdoor kg 382
Nominal Weight 2. Indoor kg 200
Rated Sound Power
db(A)
66.5

Features

  • Low profile space saving design suitable for in-ceiling installation
  • EC direct drive centrifugal blower (12-23kW)
  • EC plug fans 024-045 with high static capability up to 500pa
  • Hybrid axial fan (12-45kW)
  • TXV refrigerant control
  • Condenser coil anti-corrosion protection
  • Open controls
  • 25mm PE closed cell insulation
  • Phase fail protection relay
  • MEPS certified

Factory options customised to order Outdoor

  • Compressor soft starter
  • Copper/copper coil(s)
  • Capacity modulation control
  • High static pressure outdoor fans
  • Outdoor coil(s) with anti-corrosion post-treatment
  • Outdoor coil guards, powder coated
  • Discharge & suction isolation valves
  • High Level Interface (HLI) Modbus connectivity
  • Cable markers

Indoor

  • Double layered insulation to indoor section
  • Copper/copper coil(s)
  • Indoor coil(s) with anti-corrosion post-treatment

Factory options engineered to order Outdoor

  • 316 stainless steel cabinet, unpainted
  • 304 stainless steel cabinet, powder coated
  • Stainless steel external fixings
  • Coil(s) copper / copper
  • Power supply – no neutral (415/3/50)
  • Ductable air off in lieu of standard axial
    Indoor
  •  Stainless steel external fixings
  • Coil(s) copper / copper
  • Power supply – no neutral (415/3/50)
  •  R22/R407C application

Apac S030ILR / S030OVR 31.02 kW Split Ducted Unit (Low Profile) – Brochure

air conditioning enquiry