| MODEL | LGH-25RVX3-E | ||
|
25% (Default speed 1)
|
Air Volume
|
m3 /h | 63 |
| l/s | 17 | ||
| External Static Pressure | Pa | 8 | |
|
Temperature Exchange Efficiency
|
Heating % | 88 | |
| Cooling % | 85 | ||
|
Enthalpy Exchange Efficiency
|
Heating % | 84 | |
| Cooling % | 73 | ||
| Specific Fan Power | W/(l/s) | 0.63 | |
| Input Power | W | 11 | |
| Sound Pressure Level | dB(A) | 17 | |
|
50% (Default speed 2)
|
Air Volume
|
m3 /h | 125 |
| l/s | 35 | ||
| External Static Pressure | Pa | 30 | |
|
Temperature Exchange Efficiency
|
Heating % | 81 | |
| Cooling % | 79 | ||
|
Enthalpy Exchange Efficiency
|
Heating % | 75.5 | |
| Cooling % | 65 | ||
| Specific Fan Power | W/(l/s) | 0.6 | |
| Input Power | W | 21 | |
| Sound Pressure Level | dB(A) | 19.5 | |
|
75% (Default speed 3)
|
Air Volume
|
m3 /h | 188 |
| l/s | 52 | ||
| External Static Pressure | Pa | 68 | |
|
Temperature Exchange Efficiency
|
Heating % | 78.5 | |
| Cooling % | 76.5 | ||
|
Enthalpy Exchange Efficiency
|
Heating % | 72 | |
| Cooling % | 60.5 | ||
| Specific Fan Power | W/(l/s) | 0.81 | |
| Input Power | W | 42 | |
| Sound Pressure Level | dB(A) | 25 | |
|
100% (Default speed 4)
|
Air Volume
|
m3 /h | 250 |
| l/s | 69 | ||
| External Static Pressure | Pa | 120 | |
|
Temperature Exchange Efficiency
|
Heating % | 75.5 | |
| Cooling % | 70.5 | ||
|
Enthalpy Exchange Efficiency
|
Heating % | 69 | |
| Cooling % | 56 | ||
| Specific Fan Power | W/(l/s) | 1.08 | |
| Input Power | W | 75 | |
| Sound Pressure Level | dB(A) | 30.5 | |
| DUCT SIZE | mm | 150 | |
| WEIGHT | kg | 22 | |
| DIMENSIONS WXDXH | mm | 780 x 735 x 289 | |
| ELECTRICAL POWER SUPPLY | 220-240V, 50Hz | ||
| Maximum Current | A | 0.88 | |
| FUSE RATING (BS88) – HRC (A) | A | 6 | |
| HEAT EXCHANGER | Paper with specially treated Cellulose Membrane | ||
| STANDARD FILTER | ISO 16890 Coarse 60%* | ||