ActronAir Variable Systems – Commercial Package Solutions

Flexible and easy to install for reliable comfort control

Built to handle the extremes of Australia’s climate, our Standard Commercial Package Unit delivers consistent, year-round temperature control in small to medium-sized commercial spaces. With a wide operating range, flexibility of connection, durability and ease of installation also make them ideal for retrofitting older buildings or upgrading existing systems without extensive modifications.

Versatile Application Perfect for a wide range of smaller commercial spaces, including retail stores, offices, restaurants, cafes and warehouses.
15kW-200kW Variable Speed Compressor | R410A & R32 Refrigerant | Variable Speed Indoor Fan* | Multiple Handing Options* | BMS Option*

 

ActronAir Variable Speed Systems

System Brochures
GENESIS – 15kW & 17kW (R32)  | GENESIS – 96kW (R32) | Variable Capacity Commercial – 15kW – 33kW | Variable Capacity Commercial – 72kW – 96kW | Hercules – 140kW & 200kW

    Air Conditioning Online Commercial Product Enquiry

    Flexible and easy to install for reliable comfort control

    Built to handle the extremes of Australia’s climate, our Standard Commercial Package Unit delivers consistent, year-round temperature control in small to medium-sized commercial spaces. With a wide operating range, flexibility of connection, durability and ease of installation also make them ideal for retrofitting older buildings or upgrading existing systems without extensive modifications.

    Versatile Application Perfect for a wide range of smaller commercial spaces, including retail stores, offices, restaurants, cafes and warehouses.
    15kW-200kW Variable Speed Compressor | R410A & R32 Refrigerant | Variable Speed Indoor Fan* | Multiple Handing Options* | BMS Option*

     

    ActronAir Variable Speed Systems

    System Brochures
    GENESIS – 15kW & 17kW (R32)  | GENESIS – 96kW (R32) | Variable Capacity Commercial – 15kW – 33kW | Variable Capacity Commercial – 72kW – 96kW | Hercules – 140kW & 200kW

      Air Conditioning Online Commercial Product Enquiry

       

       

       

       

       

      ActronAir Variable Speed Systems – Commercial Package Solutions Specifications

      Genesis: A Smarter Start to a Sustainable Future

      Where innovation and purpose come together to elevate air conditioning for Australia’s commercial
      spaces. Designed to meet today’s needs and tomorrow’s opportunities, GENESIS offers more than just a product—it’s a commitment to delivering smarter, more efficient solutions. Grounded in sustainability and built for reliable performance, GENESIS ushers in a new era of practical, forward-thinking air conditioning

      Genesis Specifications

      Three Phase
      PRV15BT-T PRV17BT-T
      1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2)
      Cooling 14.8 17
      Heating 15 17.6
      Nett (Rated) Capacity (kW) (AS/NZS3823.1.2)
      Cooling (Min/Rated/ ) 4.49 / 14.80 / 16.50
      4.65 / 17.00 / 18.80
      Heating (Min/Rated/ ) 4.48 / 15.00 / 17.50
      5.30 / 17.60 / 19.10
      Input Power (kW) (AS/NZS3823.1.2)
      Cooling 4.42 4.99
      Heating 4.08 4.69
      2 EER Rated (AS/NZS3823.1.2)
      3 COP Rated (AS/NZS3823.1.2)
      Cooling 3.34 3.4
      Heating 3.67 3.75
      Power Supply – (V / Ph / Hz) 400V / 3Ph + N / 50Hz
      Rated Amps (AS/NZS3823.1.2) 9 9.9
      Full Load Amps (AS/NZS3823.1.2) 13.8 15.2
      4 Circuit Breaker Amps (Suggested) 16
      IP Rating IP44
      Compressor
      Type / No. per Unit Inverter Variable Speed Scroll / 1
      Starting Method Inbuilt Soft Starting
      No. of refrigeration Circuits / No. Capacity Stages (Capacity range) 1 / Variable Capacity
      Refrigerant R32
      Outdoor Variable Speed EC Motor / Direct x 2
      Fans (Type x Number per unit) Indoor Twin Deck Centrifugal / ECM Direct Drive x 1
      Airflow Range Indoor (l/s)
      Maximum 920 1060
      Nominal 770 890
      Minimum 620 710
      Unit Dimensions (mm)
      Depth 1136
      Height 1166
      Width 1523
      5 Nominal Weight (kgs) 233 242
      6 Sound Pressure Level (dBA)
      7 Sound Power Level (dBA)
      Outdoor ( Quiet / Rated / Tru-Max ) 47.3 / 56.0 / 56.1
      47.4 / 55.9 / 55.9
      Outdoor ( Quiet / Rated / Tru-Max ) 47.2 / 55.9 / 55.9
      47.5 / 56.0 / 56.1
      MEPS Certified Yes
      8 Demand Response Capability (AS4755.3) Capable

       

       

      PRV15BT-T PRV17BT-T
      LC7-2W (White) or LC7-2G (Grey) Wall Controller Optional Optional
      2nd and 3rd Wall Controller Optional Optional
      NEO Touch Wall Controller (Up to 2) Optional Optional
      Blue Epoxy Coat Coil Fin Protection – Indoor & Outdoor Coils Standard Standard
      Remote Temperature Sensor Optional Optional
      Remote ON / OFF Capability Standard Standard
      Manual Inputs Capable for Third Party Control Standard Standard
      Phase Sequence Protection Standard Standard
      Close Cell Foil Faced Insulation Standard Standard
      Removable louvre guard protection for easy cleaning Standard Standard
      Fault Indication Standard Standard
      Low Ambient Cooling (+5°C) Standard Standard
      BMS Compatibility Optional Optional
      Compressor Sound Jacket Optional Optional
      Compressor Soft Start via VSD Controller Standard Standard
      Turbo Mode Standard Standard
      K – Coil Protection (Outdoor) Optional Optional
      L – Coil Protection (Indoor) Optional Optional
      Z – Compressor 3-Phase Soft Starter (Outdoor Unit) N/A N/A
      V – Vertical Discharge Fan Coil Optional Optional
      Refrigerant Factory Charge – (g) 2450 2730
      Condensate Drain Connection – Size 25 mm ID BSP
      Air Duct Connection
      Supply Duct H x W – (mm) 200 x 740 mm
      Return Duct H x W – (mm) 348 x 1100 mm

       

       

      Genesis Commercial Package ( R32 ) 96kw – Specifications

      Technical Information
      PACKAGE UNIT
      PACKAGE OUTDOOR / INDOOR MODEL PRV96AT
      Total (Gross) Capacity (kW) (AS/NZS3823.1.2)
      Cooling (Rated) 96
      Heating (Rated) 97
      Net (Rated) Capacity (kW) (AS/NZS3823.1.2)
      Cooling (Min / Rated / TruMax)
      17.48 / 96.00 / 106.20
      Heating (Min / Rated / TruMax)
      16.57 / 97.00 / 109.00
      Input Power (kW) (AS/NZS3823.1.2)
      Cooling (Rated) 25.9
      Heating (Rated) 25.05
      EER Rated (AS/NZS3823.1.2) COP Rated (AS/NZS3823.1.2)
      Cooling (Rated) 3.71
      Heating (Rated) 3.87
      EER Tru-Max Cooling (Tru-Max) 3.33
      COP Tru-Max Heating (Tru-Max) 3.34
      Seasonal Performance Factor Commercial
      TCSPF (Hot / Mixed / Cold)
      5.085 / 5.114 / 5.521
      HSPF (Hot / Mixed / Cold)
      4.331 / 3.809 / 3.172
      Power Supply – (V / Ph / Hz) Package / Outdoor
      400V / 3Ph + N / 50h
      Rated Amps (AS/NZS3823.1.2) 40
      Full Load Amps (AS/NZS3823.1.2) Outdoor / Indoor / Total
      52.69 / 8.71 / 61.4
      Circuit Breaker Amps (Suggested) 63
      IP Rating Outdoor IP44
      Compressor
      Type / No. per Unit
      Inverter Variable Speed Scroll / 2
      Starting Method
      Inbuilt Soft Starting
      No. of refrigeration Circuits / No. Capacity Stages
      2 / Variable Capacity
      Refrigerant R32
      Fans (Type x Number per units) Outdoor
      Variable Speed ECM / Direct Drive Axial Fan x 2
      Airflow Indoor (l/s)
      Maximum 6000
      Nominal 5000
      Minimum 2250
      Package Dimensions (mm)
      Depth 2960
      Height 2400
      Width 2260
      Nominal Weight (kgs) Package 1473
      Sound Pressure Level (dBA) Outdoor (Quiet / Rated / Tru-Max
      61.0 / 68.0 / 69.0
      Sound Power Level Outdoor (Quiet / Rated / Tru-Max)
      77.5 / 84.5 / 85.6
      MEPS Certified Yes

      Advanced performance with flexible options

      Our Variable Capacity Commercial series offers businesses of all sizes an energy-efficient air conditioning solution that is packed with added value. The advanced control functionality allows for precise temperature regulation, while the unit design is easy to install and service. With a range of configuration choices, the Variable Capacity Commercial series is perfect for any commercial application. Talk with our Sales Team 1300 367 152

      Three Phase
      PRV15AT-T PRV17AT-T PKV210T-T PKV240T-T
      1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2)
      Cooling 14.95 17.35 19.52 21.32
      Heating 15.7 18.05 19.73 22.87
      Nett (Rated) Capacity (kW) (AS/NZS3823.1.2)
      Cooling (Min/Rated/ ) 5.86 / 14.65 / 16.50 6.80 / 17.00 / 18.50 7.60 / 19.12 / 21.13
      8.40 / 20.82 / 24.12
      Heating (Min/Rated/ ) 6.40 / 16.00 / 17.60 7.36 / 18.40 / 18.60 8.40 / 20.12 / 23.42
      9.66 / 23.37 / 25.21
      Input Power (kW) (AS/ NZS3823.1.2)
      Cooling 4.37 5.09 5.76 6.32
      Heating 4.56 5.25 5.28 6.88
      2 EER Rated (AS/NZS3823.1.2)
      3 COP Rated (AS/NZS3823.1.2)
      Cooling 3.35 3.34 3.32 3.3
      Heating 3.51 3.5 3.81 3.4
      Power Supply – (V / Ph / Hz) 400V / 3Ph + N / 50Hz
      Rated Amps (AS/NZS3823.1.2) 8.5 9.7 11.4 12.2
      Full Load Amps (AS/NZS3823.1.2) 16 17.8 20 21.3
      4 Circuit Breaker Amps (Suggested) 20 25
      IP Rating IP44
      Compressor
      Type / No. per Unit Tru-Inverter Variable Speed Scroll / 1
      Starting Method Inbuilt Soft Starting
      No. of refrigeration Circuits / No. Capacity Stages (Capacity range) 1 / Variable Capacity
      Refrigerant R32 R-410A
      Outdoor Axial / External Rotor / Direct Drive x 2
      Fans (Type x Number per unit) Indoor Twin Deck Centrifugal / ECM Direct Drive x 1
      Airflow Range Indoor (l/s)
      Maximum 920 1060 1200 1320
      Nominal 770 890 1000 1100
      Minimum 620 710 800 880
      External Static Pressure (Pa) – Evaporator Fan
      Maximum Airflow 147 62 213 159
      Nominal Airflow 232 187 295 269
      Unit Dimensions (mm)
      Depth 1136 1310
      Height 1166 1170
      Width 1523 1710
      5 Nominal Weight (kgs) 233 242 316 331
      6 Sound Pressure Level (dBA)
      7 Sound Power Level (dBA)
      Outdoor (low/high fan) 46.6 / 53.4 50.0 / 53.0 49.0 / 59.0 52.0 / 60.0
      Outdoor (low/high fan) 63.6 / 70.4 69.3 / 72.1 68.2 / 77.0 72.0 / 78.4
      MEPS Certified Yes

       

       

      Technical Specifications – Package Light Commercial Variable Unit 29.90-32.40kW

       

      PKV290T-T PKV290T-L/R PKV330T-T PKV330T-L/R
      1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2)
      Cooling 30.7 30.05 33.9 33.2
      Heating 28.2 28.85 31.6 32.7
      Nett (Rated) Capacity (kW) (AS/NZS3823.1.2)
      Cooling 29.90 (11.96 – 29.90) 29.20 (11.68 – 29.20) 33.00 (13.20 – 33.00)
      32.40 (12.96 – 32.40)
      Heating 29.00 (12.18 – 29.00) 29.70 (12.47 – 29.70) 32.50 (13.65- 32.50)
      33.50 (14.07 – 33.50)
      Input Power (kW) (AS/NZS3823.1.2)
      Cooling 8.4 8.74 10.05 9.99
      Heating 7.6 8.5 9.48 10
      2 EER Rated (AS/NZS3823.1.2)
      3 COP Rated (AS/NZS3823.1.2)
      Cooling 3.56 3.34 3.28 3.24
      Heating 3.82 3.49 3.43 3.35
      Power Supply – (V / Ph / Hz) 400V / 3Ph + N / 50Hz
      Rated Amps (AS/NZS3823.1.2) 15.2 19.7
      Full Load Amps (AS/NZS3823.1.2) 25 28
      4 Circuit Breaker Amps (Suggested) 32
      IP Rating IP44
      Compressor
      Type / No. per Unit Digital Scroll / 1
      Starting Method D.O.L.
      No. of refrigeration Circuits / No. Capacity Stages (Capacity range) 1 / Variable Capacity (40-100%)
      Refrigerant R-410A
      Fans (Type x Number per unit)
      Outdoor Axial / 6 Pole External Rotor / Direct Drive x 2
      Indoor Single Deck Centrifugal / ECM Direct Drive x 2
      Maximum 1800 2100
      Airflow Range Indoor (l/s)
      Nominal 1500 1750
      Minimum 1200 1400
      External Static Pressure (Pa)@Hi
      Maximum Airflow 290 300 180 100
      Nominal Airflow 300 300 300 300
      Unit Dimensions (mm)
      Depth 1440
      Height 1420
      Width 1840
      5 Nominal Weight (kgs) 400 399 433 432
      6 Sound Pressure Level (dBA)
      7 Sound Power Level (dBA)
      Outdoor (low/high fan) 56.9 / 60.9 58.8 / 62.8
      Outdoor (low/high fan) 73.9 / 77.9 75.8 / 79.8
      MEPS Compliant Yes Yes Yes Yes
      8 Demand Response Capability (AS4755.3) Capable Capable Capable Capable

       

       

      Technical Specifications – Package Light Commercial Variable Unit 14.00-21.00kWVCC – Variable Capacity Commercial Series (72kw – 96kw)

      Designed to deliver exceptional performance while ensuring energy efficiency, our Variable Capacity Commercial series is the ideal solution for retail and commercial applications. Powering Efficiency, Innovating Comfort: Unleashing the future of Heating & Cooling with Variable Capacity Commercial [VCC] Series  Australian made products includes NEO, outdoor and indoor unit. Superior performance with Actron’s Variable Capacity Commercial range, featuring high static EC plug fans at its core innovation and efficiency for an unmatched commercial environment.

      Technical Information
      PACKAGE UNIT SPLIT UNIT
      PACKAGE / OUTDOOR MODEL
      PKV720T
      PKV850T
      PKV960T
      CRV720T CRV850T CRV960T
      INDOOR MODEL EVA720T EVA850T EVA960T
      (1) Total (Gross) Capacity (kW) (AS/NZS3823.1.2)
      Cooling (Rated) 73.25 86.35 98.5 73.25 86.6 98.5
      Heating (Rated) 71.25 83.8 94.5 71.25 84.3 94.3
      Net (Rated) Capacity (kW) (AS/NZS3823.1.2)
      Cooling (Rated) 24.00 / 71.50 / 78.65 30.00 / 84.50 / 92.95 32.60 / 96.00 / 105.60 24.20 / 72.00 / 79.20 30.30 / 85.00 / 93.50
      32.60 / 96.00 / 105.60
      Heating (Rated) 23.20 / 73.00 / 80.30 25.35 / 85.50 / 94.05 31.10 / 97.00 / 106.70 23.20 / 73.00 / 80.30 25.50 / 86.00 / 94.60
      28.40 / 97.00 / 106.70
      Input Power (kW) (AS/NZS3823.1.2)
      Cooling (Min / Rated / TruMax) 21.25 25.6 28.45 21.41 25.28 27.92
      Heating (Min / Rated / TruMax) 22 24.9 28.15 21.81 24.85 25.84
      Input Power (kW) Tru-max
      Cooling (Rated) 24.35 30.48 35.2 25.14 31.38 35.2
      Heating (Rated) 25.9 27.03 34.76 25.49 29.11 34.76
      (2) EER Rated (AS/NZS3823.1.2)
      (3) COP Rated (AS/NZS3823.1.2)
      Cooling (Rated) 3.45 3.3 3.37 3.36 3.36 3.44
      Heating (Rated) 3.1 3.48 3.07 3.15 3.25 3.07
      EER Tru-max Cooling (Tru-max) 3.23 3.05 3 3.15 2.98 3
      COP TRU-MAX Heating (Tru-max) 3.1 3.48 3.07 3.15 3.25 3.07
      Seasonal Performance Factor Commercial
      TCSPF (Hot / Mixed / Cold) 4.76 / 4.75 / 5.03 4.76 / 4.79 / 5.09 4.88 / 5.08 / 5.46 4.81 / 4.81 / 5.09 4.90 / 4.94 / 5.25
      4.75 / 4.75 / 5.03
      HSPF (Hot / Mixed / Cold) 4.65 / 3.25 / 2.81 3.96 / 2.95 / 2.48 4.73 / 3.65 / 3.00
      3.70 / 2.78 / 2.43
      Power Supply – (V / Ph / Hz)
      Package / Outdoor 400V / 3PH + N- / 50Hz 400V / 3PH + N- / 50Hz
      Indoor 230V / 1Ph – / 50Hz and 400V / 3Ph – / 50Hz
      Rated Amps (AS/NZS3823.1.2) 33.6 39.3 42.9 33.6 39.3 42.9
      Full Load Amps (AS/NZS3823.1.2) Outdoor / Indoor / Total 47.0 / 6.0 / 53.0 56.2 / 8.93 / 65.1 65.9 / 9.1 / 75.0 47.0 / 6.0 / 53.0 56.2 / 8.93 / 65.1 65.9 / 9.1 / 75.0
      Circuit Breaker Amps (Suggested) 63 80 80 63 80 80
      IP Rating
      Outdoor IP44
      IP44
      Indoor IP20
      Compressor
      Type / No. per Unit Inverter Variable Speed Scroll / 2
      Starting Method Inbuilt Soft Starting
      No. of refrigeration Circuits / No. Capacity Stages 2 / Variable Capacity
      Refrigerant R-410A
      Fans (Type x Number per units)
      Outdoor Variable Speed ECM / Direct Drive Axial Fan x 2
      Indoor Variable Speed ECM / Direct Drive Backward Curve Plug Fan x 1 (72kW), 2 (85kW & 96kW)
      Airflow Indoor (l/s)
      Maximum 4500 5500 6000 4500 5500 6000
      Nominal 3800 4450 5000 3800 4450 5000
      Minimum 1000 1300 1500 1000 1300 1500
      Package / Outdoor Dimensions (mm)
      Depth 2710 2260 1205 1505
      Height 1910 2400 1905 2345
      Width 2375 2960 2280 2290
      Indoor Dimensions (mm)
      Depth 1190
      Height 1085 1520
      Width 2440 2425
      Nominal Weight (kgs)
      Outdoor 1096 1371 1478 700 834 906
      Indoor 296 368 387
      Sound Pressure Level (dBA) Outdoor (Quiet / Rated / Tru-Max) 63.6 / 70.2 / 70.2 63.7 / 69.0 / 69.0 63.7 / 69.0 / 69.0 63.6 / 70.2 / 70.2 63.7 / 69.0 / 69.0
      63.7 / 69.0 / 69.0
      Sound Power Level (dBA) Outdoor (Quiet / Rated / Tru-Max) 80.6 / 87.2 / 87.2 80.7 / 86.0 / 86.0 80.7 / 86.0 / 86.0 80.6 / 87.2 / 87.2 80.7 / 86.0 / 86.0
      80.7 / 86.0 / 86.0
      MEPS Certified Yes

      Hercules – The brains and brawn redefining air conditioning efficiencies.

      Hercules is the most advanced, energy efficient packaged unit ever made in Australia. The first packaged system to have twin inverter compressors, it’s big in lots of ways. Rated to a superior operating range, Hercules can handle the most extreme conditions Australia can throw at it, designed for large spaces such as warehouse stores, shopping centres, airport terminals, and car showrooms. But along with all that brawn comes some very brainy energy efficient thinking. ActronAir was the first air conditioning company to use inverter technology in a large-scale commercial air conditioner, and it allows superb flexibility.

      Technical Specifications – Split Light Commercial Variable Unit 29.90-33.00kW

      Three Phase
      PACKAGE MODEL
      PKV1400T PKV2000T
      Maximum Capacity
      Maximum Capacity
      1 Total (Gross) Capacity (kW) (AS/NZS3823.1.2)
      Cooling (Min – Max) 139.00 (33.50 – 139.00)
      194.50 (49.00 – 194.50)
      Heating 130 173.45
      Nett (Rated) Capacity (kW) (AS/NZS3823.1.2)
      Cooling 135 187.5
      Heating 134 180.45
      Nett (Rated) Input Power (kW) (AS/NZS3823.1.2)
      Cooling 44.84 61.75
      Heating 40.04 59.6
      2 EER Rated (AS/NZS3823.1.2)
      3 COP Rated (AS/NZS3823.1.2)
      Cooling 3.01 3.04
      Heating 3.35 3.03
      Power Supply (V / Ph / Hz) 400V / 3Ph + N / 50Hz
      Rated Amps (AS/NZS3823.1.2) 71.6 86
      Full Load Amps (AS/ NZS3823.1.2) 89.9 117
      4 Circuit Breaker Amps 100 125
      IP Rating IP44
      Compressor
      Type / No. per Unit Variable Capacity Scroll with Inverter Drive / 2
      Starting Method Soft Start
      No. of Refrigeration Circuits/Capacity Range 2 / Variable
      Refrigerant R410A
      Fans (Type x Number per unit)
      Outdoor Variable Speed ECM / Direct Drive Axial Fan x 4
      Indoor Variable Speed ECM / Direct Drive Backward Curve Plug Fan x 4
      Airflow Indoor (l/s)
      Maximum 8880 11200
      Nominal 7400 9900
      Minimum 5920 7920
      External Static Pressure (Pa) at:
      Maximum Airflow 500 500
      Nominal Airflow 500 500
      Unit Dimensions (mm)
      Depth 5250
      Height 2360
      Width 2300
      5 Nominal Weight (kgs) 2716 3012
      6 Sound Pressure Level (dBA)
      7 Sound Power Level (dBA)
      Outdoor (high/maximum) 59.1 / 66.2 66.2 / 66.2
      Outdoor (high/maximum) 76.1 / 83.2 83.2 / 83.2
      MEPS Certified Yes

       

      ActronAir Commercial Product Categories: ActronAir Variable Systems – Commercial Split Ducted Solutions  | ActronAir Split Ducted Tri-Capacity Systems | ActronAir Fixed Speed – Commercial Split Ducted Solutions | ActronAir Variable Speed Commercial Rooftop Package UnitsActronAir Variable Systems – Commercial Package Solutions | ActronAir Tri-Capacity Systems – Commercial Package Solutions | ActronAir Fixed Speed Commercial Ducted Package Units | ActronAir Ecoflex Mini VRF – Commercial Split Ducted Solutions | ActronAir Cascade Inverter Cassette System Air Conditioner

      ActronAir Residencial Product Categories: Actron Air Wall Split Systems Serene Series 2  – Actron Air Ducted Systems Advance B | Advance | Aires Split Ducted Systems | Ultra Slim Low Profile – Actron Air Multi Systems Multi Elite Series 2 – Actron Air Cascade Inverter Cassette Systems

      air conditioning enquiry