| Outdoor Unit | MXZ-4F71 VGD-A1 | |
| Refrigerant | R32 | |
| Precharge Refrigerant | 2.4 | |
| Power Supply (V, Phase, Hz) | 220V, single, 60Hz / 230V, single, 50Hz | |
|
Cooling Heating |
Capacity [Min-Rated- kW Max]
Total Input [Rated] kW AEER/EER Running Current [Rated] A [220V/60Hz – 230V/50Hz] |
3.7 – 7.1 – 8.8 |
| 1.79 | ||
| 3.93/3.97 | ||
| 8.3 – 7.9 | ||
| Sound Pressure Level Out [PWL] | 63 | |
| Capacity [Min-Rated- kW Max] |
3.4 – 8.0 – 10.7 | |
|
Total Input [Rated] kW ACOP/COP
Running Current [Rated] A [220V/60Hz – 230V/50Hz] |
1.67 | |
| 4.74/4.79 | ||
| 7.7 – 7.4 | ||
| Sound Pressure Level Out [PWL] | 66 | |
| Max. Running Current A | 18 | |
|
Breaker Size
Outdoor Dimensions [HxWxD]mm |
25 | |
| 710 x 840 x 330 | ||
| Unit Weight kg | 59 | |
|
Piping
|
Diameter [Gas/Liquid] mm | 9.52 x 3 + 12.7 x 1 / 6.35 x 4 |
| Max. Length m [Total-Each] |
60 – 25 | |
|
Max. Height
Guaranteed Operating Range [Outdoor] |
15 /10 *1 | |
| Cooling °C | -10 ~ 46 | |
| Heating °C | -15 ~ 24 | |