| CAPACITY | 10.0 KW | |||
| Set | FDU100AVNAWVH | |||
| Indoor | FDU100VH | |||
| Outdoor | FDCA100VNA-W | |||
| Power Source (Outdoor Unit) | 1 Phase 240V 50Hz | |||
|
*Operation Data |
Nominal Capacity Range |
Cooling T1 |
kW |
10.0 (4.0-11.2) |
| Heating H1 | 11.2 (4.0-12.5) | |||
| Heating H2 | 10.00 | |||
|
Power Consumption |
Cooling T1 | 2.99 | ||
| Heating H1 | 2.66 | |||
| Max Power Consumption | 6.40 | |||
|
Running Current |
Cooling T1 |
A |
14.3 | |
| Heating H1 | 12.7 | |||
| Inrush Current, Maximum Current | 5, 26 | |||
| EER | Cooling T1 | 3.35 | ||
| COP | Heating H1 | 4.21 | ||
| Sound Power Level (JS C9612) | Outdoor |
dB(A) |
70 | |
| Sound Pressure Level (JS C9612) | Indoor | P-Hi:44 Hi:38 Me:36 Lo:30 | ||
| Outdoor | 55 | |||
|
External Dimensions (HXWXD) |
Indoor |
mm |
280×1370×740 | |
| Outdoor | 845x970x370 | |||
|
Net Weight |
Indoor |
Kg |
54 | |
| Outdoor | 77 | |||
| Supply Air Connection |
mm |
170×1200 | ||
| Return Air Connection | 235×1280 | |||
| External Static Pressure (Max) | Pa | 200 | ||
| Airflow | Indoor (Cooling) | l/s | P-Hi: 600 Hi:467 Me:417 Lo:317 | |
| Indoor (Heating) | ||||
|
Refrigerant (Type, Amount, Pre-charge Length) |
Quantity | kg | (R32) 3.3 | |
| Pre Charged To Pipe
Length |
m | 30 | ||
|
Installation Data |
Refrigerant Piping |
Liquid Line |
mm |
Ø9.52 |
| Gas Line | Ø15.88 | |||
| Connection Method | Flare Connection | |||
| Maximum Pipe Length (One Way) |
m |
50 | ||
|
Max vertical height diff. between O.U. and I.U. |
50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. ) |
|||
| Controller | RC-E5, RC-EXZ3A, RCH-E3 or RCN-KIT4-E2 | |||
| Motion Sensor (Optional) | LB-KIT2 | |||
| Demand response (AS4755) | Yes | |||
| Outdoor air temperature (upper, lower limits) | Cooling |
oC |
-15 to 50 | |
| Heating | -20 to 20 | |||
Mitsubishi Heavy Industries FDU100AVNAWVH 10.0kW Slimline Ducted Air Conditioner System 1 Phase
10.0 kW Cooling | 11.2 kW Heating | 1 Phase
Mitsubishi Heavy Industries FDU100AVNAWVH 10.0kW Slimline Ducted System
Indoor FDU100VH | Outdoor FDCA100VNA-W
Includes RC-EXZ3A Wired Controller | Dry Operation to reduce Humidity
5 Years Manufacturer’s Warranty | 30m Precharged and 50m max pipe length
The FDU series of ducted air conditioning systems are a quiet and discreet climate solution for your entire home. Ranging from 7.1kW up to 14kW, the FDU series incorporates a compact design, a range of convenient features and functions including high power mode, silent mode and several timer and scheduling functions.
POWER: Single Phase & Three Phase | AVAILABLE IN: Reverse Cycle
CAPACITIES: 7.1kW | 10.0kW | 12.1kW |12.5kW | 14.0kW
Key features
- Slimline design
- High Power Mode for rapid cooling and heating
- Weekly & Sleep timers
- Silent operation
- Dry operation to reduce humidity
Description
10.0 kW Cooling
11.2 kW Heating
Slimline design | Silent Operation